​OF HIGH RELIABILITY CRYSTAL OSCILLATORS

THE WORLD'S LEADING MANUFACTURER​​

Q-Tech Corporation

(310) 836-7900

For space level products, Q-Tech offers Screening and Quality Conformance testing in accordance with - or superior to - MIL-PRF-55310 and MIL-PRF-38534. Our application note describing the differences in these requirements can be found here.

GROUP C

  • VIBRATION (Sinusoidal) non-operating per MIL-STD-202, Method 204, per MIL-PRF-55310
  • SHOCK (Specified Pulse) per MIL-STD-202, Method 213 (non-operating)
  • THERMAL SHOCK per MIL-STD-202, Method 107
  • AMBIENT PRESSURE (operating and non-operating) per MIL-STD-202, Method 105, and MIL-PRF-55310
  • STORAGE TEMPERATURE per MIL-PRF-55310
  • RESISTANCE TO SOLDERING HEAT per MIL-STD-202, Method 210
  • MOISTURE RESISTANCE per MIL-STD-202, Method 106
  • SALT SPRAY per MIL-STD-883, Method 1009
  • TERMINAL STRENGTH per MIL-STD-202, Method 211
  • RESISTANCE TO SOLVENTS per MIL-STD-202, Method 215
  • Visual Inspection
  • Shock
  • Vibration
  • Temperature Cycling
  • Seal
  • Solderability
  • Thermal Shock
  • Steady State Life
  • Ambient Pressure
  • Constant Acceleration
  • Destructive Bond Pull
  • Salt Spray
  • ... and Many More

Test Methods

Every 24 months, a Group C Inspection on MIL-PRF-55310 products is performed.  The test data is reviewed and approved by DSCC. This data becomes generic test data which is available for the customer upon request.

GROUP C TESTING